Construction Systems / Standard
Construction system

Standard

Technical details

  1. Fire-resistant plasterboard (GKF): 12.5 mm
  2. Fibreboard: 15 mm
  3. Vapour barrier: 0.2 mm
  4. Thermal and sound insulation (rock wool, λ = 0.038 W/m2K) between load-bearing construction: 120 mm
  5. Wooden load-bearing construction: 120 mm
  6. Fibreboard: 15 mm
  7. Thermal and sound insulation (styrofoam EPS λ = 0.039 W/m2K): 140 mm
  8. Reinforced mortar and grid: 4 mm
  9. Exterior façade layer: 2 mm

THICKNESS: 313 mm
THERMAL INSULATION: 0.15 W/(m2K)
SOUND INSULATION: Rw ≥ 45 dB
FIRE RESISTANCE: REI 60 min
PHASE DELAY: +8 h

The basic construction system for building nearly zero-energy buildings. It offers excellent utilisation of space and good insulation.

The Standard construction system consists of a basic load-bearing construction, which is insulated with a 140mm of facade insulation. All Rihter construction systems have load-bearing boards lined on both sides of the load-bearing construction. This greatly increases the seismic stability of the structure. Lining the load-bearing construction on both sides ensures increased stability and rigidity of your house in case of an earthquake.